• There is 1 heat exchanger in the Solitank boiler and 4 sleeves connected to the tank body. The domestic water is heated instantaneously from the upper heat exchanger. In the sleeves connected to the tank body, the water can be heated by a heater (heat pump, boiler) and used in the heating supply.
• Solitank can store simultaneously in 2 different variants according to system requirements. Can be used as domestic hot water + buffer tank.
• The hot water stored in the tank is used both for heating support and for heating domestic water.
• The 1 heat exchangers in the boiler are made of Chrome-Nickel 316L stainless steel.
• Since the domestic water is heated instantly from the heat exchanger, they are hygienic boilers where Legionella and other bacteria do not grow.
• The domestic hot water heat exchanger made of Chrome-Nickel 316L stainless steel provides almost twice the surface area compared to rigid pipe applications. Larger surface area means better heat transfer capacity and higher efficiency.
• Since the water stored in the tank is filled once, corrosion does not occur in any way. The anode rod and similar corrosion protection materials are not required. Maintenance work such as replacing the anode rod or cleaning the boiler is therefore not necessary.
• Optionally can be operated with electric heater.
• When choosing a non-solar heat source, this is the most efficient model.
• Perfectly compatible with heat pumps.
• In order to minimize SOLITANK heat losses, 200-500 liters of high-strength rigid polyurethane insulation material with a thickness of 50mm and a density of 40 kg/m³ is used. Sponge insulation with a density of 18 kg/m³ is used in 500-800 and 1000 lt.
PRODUCT CODE | SOLITANK 200 MA-0001 | SOLITANK 300 MA-0002 | SOLITANK 500 MA-0492 | SOLITANK 1000 MA-0493 |
---|---|---|---|---|
Height (mm) | 1245 | 1770 | 1653 | 2033 |
Diameter (mm) | 542 | 542 | 750/807 | 1017 |
Net Weight (kg) | 75 | 85 | 100 | 190 |
Volume / Cubage (lt) | 170 | 245 | 454 | 970 |
Insulation | 50 mm / 40 kg/m³ | 50 mm / 40 kg/m³ | 50 mm / 40 kg/m³ – 80 mm / 18 kg/m³ | 80 mm / 18 kg/m³ |
Insulating Material | Polyurethane (CFC Free) | Polyurethane (CFC Free) | Polyurethane / 18 Density Foam Rubber (CFC Free) | 18 Density Foam Rubber |
Outer Cylinder Materials | Electrostatic Powder Painted ST 37 Steel | Electrostatic Powder Painted ST 37 Steel | Electrostatic Powder Painted ST 37 Steel / Leatherette Jacket | Leatherette Jacket |
Material of Coil | AISI 316 L Stainless Steel | AISI 316 L Stainless Steel | AISI 316 L Stainless Steel | AISI 316 L Stainless Steel |
Number of Coils | 1 | 1 | 1 | 1 |
1. Serpantina Area (m²) | 3,83 | 3,83 | 5,48 | 8,76 |